Model | FD-Q10C | FD-Q20C | FD-Q32C | FD-Q50C | |||
Image |
|
|
|
| |||
Supported pipe diameter | 1/4" (8 A), ø13 to ø16 (mm) | 1/2" (15 A), ø18 to ø23 (mm) | 1" (25 A), ø28 to ø37 (mm) | 1 1/2" (40 A), ø44 to ø52 (mm) | |||
Supported pipe materials | Metal pipe/Resin pipe*1 | ||||||
Supported fluids | Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1 | ||||||
Supported fluid temperature | 0 to 85°C (No freezing on the pipe surface)*2 | ||||||
Maximum rated flow | 1/4" (8 A): 20 L/min | 1/2" (15 A): 60 L/min | 1" (25 A): 200 L/min | 1 1/2" (40 A): 400 L/min | |||
Zero cut flow rate | 1.0 L/min (Default)*3 | 2.5 L/min (Default)*3 | 5 L/min (Default)*3 | 25 L/min (Default)*3 | |||
Display method | Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator | ||||||
Display update cycle | Approx. 3 Hz | ||||||
Display resolution | 0.01/0.1/1 (Default : 0.1) (L/min) | 0.1/ 1 (Default : 0.1) (L/min) | 0.1/ 1 (Default :1) (L/min) | ||||
Response time | 0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s | ||||||
Protection circuit | Power supply reverse connection protection, power supply surge protection, | ||||||
Repeatability | 0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4 (Specific to selected response time)) | ||||||
Hysteresis | Variable | ||||||
Integrated flow unit display | 0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L) | 1/ 10/ 100/ 1000/ 10000 (Default : 1) (L) | |||||
Integrated flow data storage cycle | Save to memory every 10 seconds | ||||||
Memory backup | EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more) | ||||||
Power I/O connector | M12 4-pin connector | ||||||
Input/Output (Selectable) | Output (ch.1/ch.2) | Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), | |||||
Analogue output (ch.1/ch.2) | 4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5 | ||||||
External input (ch.2) | Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), | ||||||
Power supply | Power voltage | 20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS | |||||
Current consumption | 100 mA or less (Load current excluded)*6 | 130 mA or less (Load current excluded)*6 | |||||
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) | |||||
Ambient temperature | -10 to +60 °C (No freezing) | ||||||
Relative humidity | 35 to 85 % RH (No condensation) | ||||||
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | ||||||
Shock resistance | 100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||||||
Material | Sensor main unit | PPS/PES/PBT/SUS303/SUS304/SUSXM7 | |||||
Sensor surface | Rubber | ||||||
Mounting bracket | SUS304/PA/SUSXM7 | SUS304/PA/POM/SUSXM7 | |||||
Weight | Approx. 340 g (including mounting bracket) | Approx. 400 g (including mounting bracket) | Approx. 530 g (including mounting bracket) | Approx. 640 g (including mounting bracket) | |||
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes) |
Specs : Clamp-on Flow Sensor - FD-Q series (2024)
Top Articles
Latest Posts
Article information
Author: Jeremiah Abshire
Last Updated:
Views: 6262
Rating: 4.3 / 5 (54 voted)
Reviews: 93% of readers found this page helpful
Author information
Name: Jeremiah Abshire
Birthday: 1993-09-14
Address: Apt. 425 92748 Jannie Centers, Port Nikitaville, VT 82110
Phone: +8096210939894
Job: Lead Healthcare Manager
Hobby: Watching movies, Watching movies, Knapping, LARPing, Coffee roasting, Lacemaking, Gaming
Introduction: My name is Jeremiah Abshire, I am a outstanding, kind, clever, hilarious, curious, hilarious, outstanding person who loves writing and wants to share my knowledge and understanding with you.